Public tenders for power-transformer in Germany

Find all Energy tenders in the world.
Finding business opportunities has never been easier.

Results for energy. Make a new search!

Three-winding power transformer.

Energiedienst Holding AG | Published January 31, 2014  -  Deadline February 28, 2014
cpvs
31174000

1x three-winding power transformer.

Renewal power transformer 13 10 / 0,4kV, 1600kVA

Staatsbetrieb Sächsisches Immobilien- und Baumanagement, Niederlassung Chemnitz | Published March 28, 2018  -  Deadline April 12, 2018
cpvs

Renewal power transformer 13 10 / 0,4kV, 1600kVA

40 MVA power transformer UW Emst.

Mark-E Aktiengesellschaft | Published September 3, 2014  -  Deadline October 3, 2014
cpvs
31170000, 31171000, 51111300

Mixed type contract: construction. Manufacture, supply, installation and commissioning of a 40 MVA three-phase power transformer for use as adjustable 110/10 kV power transformer for the substation Emst The transformer is to create in oil / air-cooled version with self-cooling to 100% of rated output (ONAN). The transformer is largely run by RWE-design specification.

Power transformer

SWM Infrastruktur GmbH | Published September 16, 2014
cpvs
31170000

Leistungstrafo

Three-winding power transformer.

Energiedienst Holding AG | Published August 16, 2014
cpvs
31174000

Dreiwickler Leistungstransformator.

Power transformer, supply and commissioning

TU-Darm­stadt, Bau­ma­na­ge­ment III | Published October 16, 2014
cpvs
31100000

Netztransformator, Lieferung und Inbetriebnahme

Delivery, transportation and ready-erection of 8 medium-power transformers.

Westfalen Weser Netz GmbH | Published September 3, 2014  -  Deadline September 15, 2014
cpvs
31171000

The Westfalen Weser Netz GmbH intends some of their substations in Paderborn, Bad Lipps rings, Hagen, Enger, frets and Bad Eilsen equip it with new medium-power transformers. It is planned procurement of the following 8 medium power transformers. UW Neuenbeken: 1 piece medium power transformer OS: 115 kV, U.S.: 20 kV (Rated voltage) with a rated power of 40/50 MVA (variant 1) or 63/80 MVA (variant 2) UW Lippspringe: 1 piece medium power transformer OS: 115 kV, U.S.: 20 kV (Rated voltage) with a rated power of 25 / 31.5 MVA UW Talle: 1 piece medium power transformer OS: 115 kV, U.S.: 20 kV (Rated voltage) with a rated power of 40/50 MVA UW Hagen: 1 piece medium power transformer OS : 115 kV, U.S.: 10 kV (Rated voltage) with a rated output of 31.5 / 40 MVA UW Passenger: 1 piece medium power transformer OS: 115 kV, U.S.: 10 kV (Rated voltage) with a rated output of 31.5 / 40 MVA UW Kling Street: 1 piece medium power transformer OS: 30 kV, U.S.: 10 kV (Rated voltage) with a rated power of 10 / 12.5 MVA UW Heeßen: 2 piece medium power transformers OS: 30 kV, U.S.: 10 kV (Rated voltage) with a rated power of 10 / 12.5 MVA is important that the Verlademaß the transformers is 900 mm. Furthermore, the design according to "Technical Specification for medium power transformers", Stand 03.30.2014 to comply. The tender includes supply, transportation and ready-installing.

15 MVA and 10 MVA / (13 MVA) 16.7 Hz single-phase traction power transformer in the stationary version for outdoor installation in substations

Deutsche Bahn AG FEI - Beschaffung Infrastruktur | Published September 12, 2016  -  Deadline October 10, 2016
cpvs
31170000, 31171000, 31174000

15 MVA and 10 MVA / (13 MVA) 16.7 Hz single-phase traction power transformer according to the General specifications Power transformers (oil) for traction current (16.7 Hz and 50 Hz), currently valid issue with all facilities. The rated power of 10 MVA / (13 MVA) and 15 MVA traction power transformers are designed and 60076 demonstrate to IEC without limiting the life consumption. Particular attention should be paid to the dynamic short-circuit strength of the structure supporting the specificity of Bahnbetriebesmit its operational short circuits in overhead network statement. Requirements of the specifications at: DB Energie GmbH, control / switchgear (I.ETZ 22), Pfarrer-Perabo-Platz 2, 60326 Frankfurt am Main. nationwide

Framework agreement 15 MVA and 10 MVA / (13 MVA) 16.7 Hz single-phase traction power transformer in stationary design for outdoor installation in substations DB Energie GmbH.

DB Energie GmbH (Bukr 31) | Published August 29, 2014  -  Deadline September 29, 2014
cpvs
31170000, 31171000, 31174000

15 MVA and 10 MVA / (13 MVA) 16.7 Hz single-phase traction power transformer according to specifications, the current status. The rated power of 10 MVA / (13 MVA) and 15 MVA traction power transformers are in accordance with IEC 60076 interpreted and verified, without limitation, the life consumption. Particular attention shall be paid to the dynamic short-circuit strength of the structure supporting the specificity of railway operations with its operational shorts in the overhead network account. Requirements of the specifications at: DB Energie GmbH; Power distribution systems and control systems (I.EBZ 4); Pastor-Perabo-Platz 2; 60326 Frankfurt am Main.

Power Transformers

EWE NETZ GmbH | Published January 23, 2014
cpvs
65000000, 65310000

Leistungstransformatoren

Power Transformers

Vattenfall Europe Netzservice GmbH | Published January 9, 2014
cpvs
31100000, 31160000, 31170000, 31171000, 31213200, 51111300

Leistungstransformatoren

Liquid dielectric transformers

Westfalen Weser Netz GmbH | Published February 13, 2015  -  Deadline March 3, 2015
cpvs
31171000

The Westfalen Weser Netz GmbH intends her substation in Coppenbruegge be equipped with a new medium power transformer. It is planned procurement of the following means power transformer. 1 piece of medium power transformer OS: 115 kV, US: 30 kV (rated voltage) with a rated capacity of 63/80 MVA. It is important that the Verlademaß of the transformer is 900 mm. Furthermore, the design according to "Technical Specification for medium power transformers," Stand 03.30.2014 to comply. The tender includes delivery, transport and ready-installing.

Electric motors, generators and transformers

Vattenfall Wärme Hamburg GmbH | Published February 2, 2017
cpvs
31100000

Renovation Electric boilers Karoline - power transformer - Vattenfall Heat Hamburg GmbH.

Liquid dielectric transformers

Westfalen Weser Netz GmbH | Published December 20, 2016
cpvs
31171000

Supply, transport and ready-asserting a central power transformer OS: 115kV, US: 20 kV with 40/50 MVA.

County government, transformer station.

Kreisverwaltung Groß-Gerau | Published October 25, 2014
Winner
E.M.K. Elektromontagen GmbHSalzschlirfer Str. 55Schlitz 36110
cpvs
51111000

Property county government wholesale Gerau, measure rehabilitation component B, power transformer station.

Airfield Wunstorf, refurbishment heat supply; transformer station kitchen building, Verg.-Nr.: 13 E 80198th

Staatliches Baumanagement Weser-Leine | Published January 7, 2014
Winner
Osmo Anlagen GmbH & Co KGBielefelder Str. 10Georgsmarienhütte 49124
cpvs
45311200

Airfield Wunstorf, renovation of heat supply, power transformer station kitchen building, Verg.-Nr.: 13 E 80198th

16500 TenneT Qualification System (TQS) power transformers, shunt reactors.

TenneT TSO GmbH | Published August 16, 2014
cpvs
31171000

16500 TenneT Qualification System (TQS) power transformers, shunt reactors.

Transformers

DB Energie GmbH (Bukr 31) | Published December 29, 2016
cpvs
31170000, 31171000, 31174000

15 MVA and 10 MVA / (13 MVA) 16.7 Hz single-phase traction power transformer in the stationary version for outdoor installation in substations.

Liquid dielectric transformers

Westfalen Weser Netz GmbH | Published April 6, 2016
cpvs
31171000

Supply, transport and ready-asserting a central power transformer OS: 115 KV, US1: 32 KV, US2: 10 KV with 31.5 / 40 MVA

Supply, installation and commissioning of a new three-phase three-winding power transformer oil as a generator transformer in continuous operation. Execution in Odan (optional ODAF) with vacuum OLTC with 27 positions. Mains voltages; 400 kV/110 kV/30 kV rated outputs; 400 MVA/400 MVA/80 MVA rated frequency, 50 Hz short-circuit voltage, approximately 17% type; transformer oil, YNyn0d5 total weight, max. 400 t size; according to German standard track clearance (DB-ground profile consistent), max. 16.92 m long

SWM Infrastruktur GmbH | Published March 11, 2014  -  Deadline April 7, 2014
cpvs
31170000

Supply, installation and commissioning of a new three-phase three-winding power transformer oil as a generator transformer in continuous operation. Execution in Odan (optional ODAF) with vacuum OLTC with 27 positions. Mains voltages; 400 kV/110 kV/30 kV rated outputs; 400 MVA/400 MVA/80 MVA rated frequency, 50 Hz short-circuit voltage, approximately 17% type; transformer oil, YNyn0d5 total weight, max. 400 t size; according to German standard track clearance (DB-ground profile consistent), max. 16.92 m long