Call +44 800 9755 164

Public tenders for energy in Tarpa Hungary

Find all Energy tenders in the world.
Finding business opportunities has never been easier.

Results for energy. Make a new search!

"Integrated Social Tóháti center energy modernization of renewable energy"

Beregsurány Község Önkormányzata | Published November 25, 2015
Winner
RÁDIUM Ipari, Kereskedelmi és Szolgáltató Kft.
cpvs
45321000

"Tóháti Integrated Social Centre energetic modernization of renewable energy", as follows: Project location: Tóháti Integrated Social Centre 4933 Beregsurány, Árpád út 52. Tóháti Integrated Social Centre (hereinafter referred to as old people's homes) built renovating view of the fact that the building construction energy features do not meet the 7/2006. Required heat transfer coefficient (V.24.) TNM regulation values. A short guide to Energy Performance of Buildings work areas: • The exterior perimeter of the structure, skirting, front wall and roof slab thermal insulation; • Replacing the entire building facade doors and windows; • Replacement of the heating system heat generation; • Changing the domestic hot water production with an indirect storage; The building is 509 m2 net floor area of ​​the building height: 3.00 m Final finishing layer of mosaic plaster is applied bucket. Thermal Insulation: Windows, U 1.0 W / m2K plastic doors and entrance doors: U 1.1 W / m2K plastic doors and exterior walls 10 cm Polifarbe EPS nikecell heat island. Final plaster ceiling systems (attic floor): 25 cm Rockwool mineral wool insulation plate lying on ground floor: 8 cm XPS insulation system Polifarbe the plinth building services work areas: central heating works and hot water supply works, works of chimney systems. Installation of Photovoltaic Power Plant: General description Number earmarked for the PVPP for modules, location and type PVPP on the number of modules Module type Overhead 1 21 BMU250 (250Wp) Roof 2 21 BMU250 (250Wp) Roof 3 42 BMU250 (250Wp) earmarked for the PVPP for Inverters and type the number Inverter type Inverter KACO POWADOR 12.0TL3 2 includes detailed technical specifications supplied as part of the technical specification documentation.

"Integrated Social Tóháti center energy modernization of renewable energy" -2.sz. authors

Beregsurány Község Önkormányzata | Published November 25, 2015
Winner
RÁDIUM Ipari, Kereskedelmi és Szolgáltató Kft.
cpvs
45321000

"Tóháti Integrated Social Centre energetic modernization of renewable energy", as follows: Project location: Tóháti Integrated Social Centre 4933 Beregsurány, Árpád út 52. Tóháti Integrated Social Centre (hereinafter referred to as old people's homes) built renovating view of the fact that the building construction energy features do not meet the 7/2006. Required heat transfer coefficient (V.24.) TNM regulation values. A short guide to Energy Performance of Buildings work areas: • The exterior perimeter of the structure, skirting, front wall and roof slab thermal insulation; • Replacing the entire building facade doors and windows; • Replacement of the heating system heat generation; • Changing the domestic hot water production with an indirect storage; The building is 509 m2 net floor area of ​​the building height: 3.00 m Final finishing layer of mosaic plaster is applied bucket. Thermal Insulation: Windows, U 1.0 W / m2K plastic doors and entrance doors: U 1.1 W / m2K plastic doors and exterior walls 10 cm Polifarbe EPS nikecell heat island. Final plaster ceiling systems (attic floor): 25 cm Rockwool mineral wool insulation plate lying on ground floor: 8 cm XPS insulation system Polifarbe the plinth building services work areas: central heating works and hot water supply works, works of chimney systems. Installation of Photovoltaic Power Plant: General description Number earmarked for the PVPP for modules, location and type PVPP on the number of modules Module type Overhead 1 21 BMU250 (250Wp) Roof 2 21 BMU250 (250Wp) Roof 3 42 BMU250 (250Wp) earmarked for the PVPP for Inverters and type the number Inverter type Inverter KACO POWADOR 12.0TL3 2 includes detailed technical specifications supplied as part of the technical specification documentation.

"Integrated Social Tóháti center energy modernization of renewable energy" -3.sz. contract modification

Beregsurány Község Önkormányzata | Published November 30, 2015
Winner
RÁDIUM Ipari, Kereskedelmi és Szolgáltató Kft.
cpvs
45321000

"Tóháti Integrated Social Centre energetic modernization of renewable energy", as follows: Project location: Tóháti Integrated Social Centre 4933 Beregsurány, Árpád út 52. Tóháti Integrated Social Centre (hereinafter referred to as old people's homes) built renovating view of the fact that the building construction energy features do not meet the 7/2006. Required heat transfer coefficient (V.24.) TNM regulation values. A short guide to Energy Performance of Buildings work areas: • The exterior perimeter of the structure, skirting, front wall and roof slab thermal insulation; • Replacing the entire building facade doors and windows; • Replacement of the heating system heat generation; • Changing the domestic hot water production with an indirect storage; The building is 509 m2 net floor area of ​​the building height: 3.00 m Final finishing layer of mosaic plaster is applied bucket. Thermal Insulation: Windows, U 1.0 W / m2K plastic doors and entrance doors: U 1.1 W / m2K plastic doors and exterior walls 10 cm Polifarbe EPS nikecell heat island. Final plaster ceiling systems (attic floor): 25 cm Rockwool mineral wool insulation plate lying on ground floor: 8 cm XPS insulation system Polifarbe the plinth building services work areas: central heating works and hot water supply works, works of chimney systems. Installation of Photovoltaic Power Plant: General description Number earmarked for the PVPP for modules, location and type PVPP on the number of modules Module type Overhead 1 21 BMU250 (250Wp) Roof 2 21 BMU250 (250Wp) Roof 3 42 BMU250 (250Wp) earmarked for the PVPP for Inverters and type the number Inverter type Inverter KACO POWADOR 12.0TL3 2 includes detailed technical specifications supplied as part of the technical specification documentation.

24842/2015 - No. 1 Correction Notice regarding contract modification

Beregsurány Község Önkormányzata | Published December 18, 2015
cpvs
45321000

"Tóháti Integrated Social Centre energetic modernization of renewable energy", as follows: Project location: Tóháti Integrated Social Centre 4933 Beregsurány, Árpád út 52. Tóháti Integrated Social Centre (hereinafter referred to as old people's homes) built renovating view of the fact that the building construction energy features do not meet the 7/2006. Required heat transfer coefficient (V.24.) TNM regulation values. A short guide to Energy Performance of Buildings work areas: • The exterior perimeter of the structure, skirting, front wall and roof slab thermal insulation; • Replacing the entire building facade doors and windows; • Replacement of the heating system heat generation; • Changing the domestic hot water production with an indirect storage; The building is 509 m2 net floor area of ​​the building height: 3.00 m Final finishing layer of mosaic plaster is applied bucket. Thermal Insulation: Windows, U 1.0 W / m2K plastic doors and entrance doors: U 1.1 W / m2K plastic doors and exterior walls 10 cm Polifarbe EPS nikecell heat island. Final plaster ceiling systems (attic floor): 25 cm Rockwool mineral wool insulation plate lying on ground floor: 8 cm XPS insulation system Polifarbe the plinth building services work areas: central heating works and hot water supply works, works of chimney systems. Installation of Photovoltaic Power Plant: General description Number earmarked for the PVPP for modules, location and type PVPP on the number of modules Module type Overhead 1 21 BMU250 (250Wp) Roof 2 21 BMU250 (250Wp) Roof 3 42 BMU250 (250Wp) earmarked for the PVPP for Inverters and type the number Inverter type Inverter KACO POWADOR 12.0TL3 2 includes detailed technical specifications supplied as part of the technical specification documentation.

Information on the "periphery Tarpa 041 property under u. Situated sports field design and development work" adopted by the outcome procurement process

Tarpa Nagyközség Önkormányzata | Published December 16, 2015
Winner
UNISZOL Létesítménygazdálkodási Zrt. - UNIRENT HUNGÁRIA Korlátolt Felelősségű Társaság
cpvs
45000000, 71220000

The object of the procurement "Tarpa periphery 041 u. property is located under the sports field design and development work "The amount of purchases: 041 planning to implement Tarpa outskirts Contracting hrsz development. sports fields located below the property concerned. Within the project, a new soccer field and a sports locker room is built, the latter can accommodate 42 persons in the attic hostel would be established. The envisaged investment opportunities next to the current track new standard is based on a large artificial grass courts. The gross floor area of ​​about 300 sq sports changing rooms will be built (toilets, refreshments). The building will be constructed attic of a suitable hostel can accommodate 42 students. The contractor responsible for the construction of licensee plans, and the preparation of the necessary construction plans. Sports clothing and hostel building construction: During the planning of 7/2006 have been taken into account, valid from l January 2015, the energy characteristics of buildings for state subsidized investment funds of the Group. TNM specifications (24 V). The attic is arranged in a suitable hostel can accommodate 42 students, according to the regulations server rooms. Standard, full-sized artificial grass football pitch construction - will be built next to the existing grass football pitch with a new artificial turf football field, which is possible to match multiple simultaneous meetings. - Implemented within the framework of the project, any additional course accessories required by the standards: 2 to 500 persons, covered grandstand ball trap nets, the trails around the security fence, spectators and isolation players track elements (gates, flags, scoreboards, pályafestések) - transport insurance, hiking trails 5) MEW. the provisions of the Regulation. The compliance or equivalence must be verified authentic quality certificate or a declaration from an independent, professionally recognized organization, especially from the manufacturer. The contracting authority draws attention to the process of work opening the quantities listed in the invitation only serve to inform the bidders on the scale of the work and should not be considered quantitative detection of the work actually performed.
  • 1