Public tenders for flow-meter in Italy

Find all Energy tenders in the world.
Finding business opportunities has never been easier.

Results for energy. Make a new search!

FLOW METER AQUEDUCT

Comune di Gianico | Published December 5, 2016  -  Deadline August 29, 2019
cpvs

FLOW METER AQUEDUCT

Flow meters

Snam Rete Gas S.p.A. | Published February 9, 2016
cpvs

Flow meters

Flow meters.

Snam Rete Gas SpA | Published December 24, 2013
cpvs
38421000

Misuratori di portata.

Supply contract of a gas flow meter for burners of line 1 at the plant of Alto Vicentino Ambiente srl - CIG Z2B1FD73D1

ALTO VICENTINO AMBIENTE S.R.L. - SERVIZIO AFFARI GENERALI | Published September 22, 2017
cpvs

F_OSS_385 Provision of magnetic flow meters for drinking water

Alto Vicentino Servizi spa - Ingegneria e Costruzioni | Published October 31, 2017  -  Deadline October 26, 2017
cpvs

ACQ16-72 - Tender_127 Rfq_236 verification service of the drainage system with flow meters.

ACQUE VICENTINE S.P.A. - Acquisti | Published January 31, 2017  -  Deadline January 31, 2018
cpvs

Acq16-72 Tender_127 Rfq_236 verification service of the drainage system with flow meters.

ACQUE VICENTINE S.P.A. - Acquisti | Published November 11, 2016  -  Deadline November 11, 2017
cpvs

Supply, installation and commissioning of integrated flow meters of natural gas.

Edison DG SpA | Published March 5, 2014  -  Deadline March 15, 2014
cpvs
38420000

Supply, installation and commissioning of gas meters of the IIa family: natural gas (group H) measurement principle volumetric, mass, sonic, etc. .. maximum flow rate Qmax = 25 m³ / h (former class G16) and Qmax = 16 m³ / h (former class G10) that provide data to measure the gas under standard thermodynamic conditions of reference or base Vb (tb temperature equal to 288.15 K, the absolute pressure pb equal to 1.01325 bar) characterized by : - Compliance with Directive 2004/22/EC (Measuring Instruments Directive, abbreviated MID), MI-002 - Compliance with standards UNI - TS 11291 "Measurement of gas - gas measuring devices", - Compliance with requirements functional requirements contained in Resolution ARG / gas 631/2013/R/gas 12.27.2013 and subsequent amendments of the Authority for Electricity Gas and Water System - Exposure of only the measured volumes to the thermodynamic conditions of reference or base Vb. The counters will also be equipped with communication protocol CTR, DLMS / COSEM profile with point-to-point PP4. The delivery will also include: a) training activities for planning, installation and enrollment of gas meters at the SAC of the contracting entity or the download center of the supplier, to the staff of the contracting entity to be carried out as follows: No. 3 working days of classroom training, including provision of manuals and teaching materials at an office of the contracting entity, b) training in the installation and commissioning (metering) Counter: This activity should be conducted wholly or partly in the field and in the presence of staff of the contracting entity which stage of 'training' complementary and after the training referred to in paragraph a) above. c) management and meter reading of gas meters through the SAC / download center of the supplier until such time as the communication between the gas meter and SAC / download center becomes continuous and stable d) Addressing the gas meters from the SAC / download center provider to SAC contracting entity.

APPROVAL OF SPENDING AND METHOD 'OF EXPECTATIONS - SUPPLY OF FLOW METERS

BIM GESTIONE SERVIZI PUBBLICI S.P.A. - SERVIZIO LOGISTICA - ACQUISTI/APPALTI | Published April 18, 2017  -  Deadline April 18, 2017
cpvs

Services remote reading of gas flow metering equipment or = G10 - 6136 Race - 5207862FA9 IGC.

IREN SpA in nome e per conto di Genova Reti Gas | Published November 13, 2013
cpvs
65500000

Servizi di telelettura dei gruppi di misura gas di portata maggiore o uguale a G10 - Gara 6136 - CIG 5207862FA9

Provision aimed at? Installation of flow meters (and other plumbing materials) in the artifacts managed by the Gran Sasso Acqua SpA

GRAN SASSO ACQUA S.P.A. | Published April 28, 2016  -  Deadline April 29, 2016
cpvs
39715300, 38410000

Provision aimed at? Installation of flow meters (and other plumbing materials) in the artifacts managed by the Gran Sasso Acqua SpA

Provision aimed at? Installation of flow meters (and other plumbing materials) in the artifacts managed by the Gran Sasso Acqua SpA

GRAN SASSO ACQUA S.P.A. | Published September 4, 2015  -  Deadline October 26, 2015
cpvs
39715300, 38410000

Provision aimed at? Installation of flow meters (and other plumbing materials) in the artifacts managed by the Gran Sasso Acqua SpA

Supply and installation of flow meters at the service of the nodes of the subnetworks of the city of Palermo for the wells and reservoirs managed by AMAP SpA

amap spa | Published June 22, 2015  -  Deadline June 30, 2015
cpvs
41000000

Supply and installation of flow meters at the service of the nodes of the subnetworks of the city of Palermo for the wells and reservoirs managed by AMAP SpA

Ref. App. 149 / 2017- Relocation - by means of a framework agreement - of the supply of flow meters of various types and diameters, for the measurement of drinking water under pressure, for the eight districts of Abbanoa SpA

ABBANOA SPA - APPROVVIGIONAMENTI | Published August 29, 2017  -  Deadline September 15, 2017
cpvs
38421000

Open procedure for the provision of a complete service of the flowmeter and probes for the SC neurosurgery for 5 years, with an option to renew for another year, including any increase in 50% of the Hospital "G. Brotzu "of Cagliari.

Azienda Ospedaliera "G. Brotzu" | Published January 15, 2014  -  Deadline March 10, 2014
cpvs
85111000

Providing a complete service of the flowmeter and probes designed for neurosurgery.

Surgical instruments

Azienda Ospedaliera «G. Rummo» | Published October 24, 2017
Winner
HED Srl
cpvs
33169000

Annual supply of intraoperative probes and vascular flowmeter for UOC of Neurosurgery - CIG 712887341A.

Blood-testing reagents

Azienda Policlinico Umberto I di Roma — U.O.C. Provveditorato / U.O.S. Patrimonio | Published October 31, 2017
Winner
BD Biosciences
cpvs
33696200

Three-Year Service of a Diagnostic and Quality Control System for Machine-Reagent Systems for the Needs of the UOC of Immunotherapy and Transfusion Medicine of UO Policlinico Umberto I in Rome.

The service includes a machine reagent system with the following features:

Four-color flowmeter, 2 CE-IVD laser sources

Colineal laser high frequency buttons with the ability to match laser detectors.

Direct collection of emission signals, which minimizes the process of extinguishing the signals themselves.

Fluid System with Peristaltic Pumps with Pulse Dampeners, non-pressurized, electronically controlled.

Absolute volumetric count through digital volume control

injected by the peristaltic pump.

Minimum volume required

of the sample: 50μL.

Range from human platelets

to the epithelial cell lines.

Variable flow rate: preselected at 14μL / min (low) 35 μL / min (medium) 66 μL / min

(fast) or variable from user (custom) between 10 and 100uL / min, depending on the concentration of

sample.

The number of acquiring events of 10,000 cells / second

Fluorescence Sensitivity <150MESF (FITC) <100MESF (PE)

24-bit digital electronic system, 7 decades Log for a resolution of over 16 million channels

Clinical software equipped with:

specific templates for running a full range of clinical applications such as:

BD Lucocount Assay: counts residual leukocytes in the erythrocytes or platelets;

BD Plasma Count Assay: Identifies and counts residual white blood cells, red blood cells and

platelets in fresh plasma preparations;

3 or 4-color basic immunophenotype: allows counting in percentage and absolute cell count

CD4 and CD8 or the full immunophenotype TBNK, with or without the use of BD TruCOUNT ™ tubes,

by the use of lyse-no-wash lysing agents;

HLA B27 Assay: Evaluates HLA B27 positive cells;

Stem Cell Enumeration: allows counting in percentage and in absolute value of stem cells

CD34 positive emopopoietic

for an annual requirement of:

residual leukocyte count in the filtered hemogranules / 1,000 tests

counting residual cells in fresh frozen plasma / 500 tests

Absolute mobile phone counts / 3 500 tests

The supply shall include:

- reagents and calibrators in quantities required for the execution of all the above tests, a PC with monitor,

printer and toner.

- Technical assistance

- Licenses for clinical software.

  • 1