Public tenders for boiler in Sweden

Find all Energy tenders in the world.
Finding business opportunities has never been easier.

Results for energy. Make a new search!

Waste incinerators

Sundsvalls Energi AB | Published March 1, 2017  -  Deadline March 15, 2017
cpvs
42320000

Sundsvall Energi AB's (SEAB), intends to procure framework agreement with one (1) Contractors where all conditions for call-off is set regarding cleaning of the boiler by blasting soot and blasting.

SEAB hereby invite you to apply to bid in the tender.

Cleaning the boiler by blasting soot and blasting.

Dust Purification of bio boilers (16/1)

Trelleborgs Fjärrvärme Aktiebolag | Published December 14, 2016  -  Deadline January 27, 2017
cpvs
42514200, 42515000

The object consists of two complete dust removal (electrostatic precipitator), including integration with the two existing biomass-fired boilers.

Purchase of Pellet boiler to schools Älgarås (TN2016 / 752)

Mariestads Kommun | Published December 13, 2016  -  Deadline December 30, 2016
cpvs
39715200, 44621200, 45331000

Purchase of pellet boiler. Complete with built silos.

Dust Purification of bio boilers (16/1)

Trelleborgs Fjärrvärme Aktiebolag | Published December 14, 2016  -  Deadline January 27, 2017
cpvs
42514200, 42515000

The object consists of two complete dust removal (electrostatic precipitator), including integration with the two existing biomass-fired boilers.

Wood fuels

AB Gotlandshem | Published December 9, 2016
Winner
Gotlands Värmepellets AB
cpvs
09111400, 09110000

The acquisition concerns the bulk delivery of wood pellets for boiler houses in Roma, Tingstäde, Lärbro and off the island.

Construction work

Ängelholms kommun | Published February 14, 2017  -  Deadline June 13, 2017
cpvs
45000000, 45210000, 45252127, 45262700, 45262800, 45453000, 45453100, 45454000

New bassäng- and building units respectively. reconstruction of existing ditto to meet treatment requirements. Various renovation and modernization work.

Documents with names that begin with 23 belonging Attempted environmental inventories Ängelholm 17.01.2017,

Documents with names starting with 28 belonging to Annex 06.5-1 Description Pop. Boiler A Ängelholm 1/17/2017,

Documents with names that begin with 32 belonging Geohandlingar Angelholm 17.01.2017,

Documents that begins with 34 belonging Drawings Angelholm 17/01/2017.

Replacement of oil-fired boilers to geothermal Åsundagården TF 2016/874

Enköpings Kommun. | Published December 21, 2016  -  Deadline February 13, 2017
cpvs
42511110, 45211100, 45221220, 45231100, 45231112, 45232142, 45232220, 45251200, 45262220, 45300000, 45311000, 45315100, 45331000, 45331100, 45331200, 50721000, 51900000, 76340000, 76431000

Audience Ad: The procurement is publicly advertised and the bidding process is ongoing. The deadline to submit bids is 13.02.2017. The offer is valid until 13.06.2017. More information can be found by clicking on the specifications in the left menu and subtitle tenders for information on how you should proceed to tender.

District heating boiler

AB Fortum Värme samägt med Stockholms stad | Published March 28, 2017
Winner
Förvaltningsrätten i Stockholm och migrationsdomstol
cpvs
42515000

The Farsta district heating plant was built in the late fifties and is today serving as a peak load plant. Fortum plans to replace the existing boilers in the plant with one new oil fired boiler, HOB. The new boiler will be fired with light fuel oil no.1 (EO1). It shall also be designed for the possibility of firing Bio oil RME in the future. The boiler shall be directly connected to the district heating system. An economizer is not foreseen. Circulation through the boiler for the purpose of minimum flow and inlet water temperature shall be made with a separate circulation pump. The boiler is expected to be directly fired, without a flue gas fan. Combustion air shall be a mixture of indoor and outdoor air. No flue gas filter is foreseen initially.

The thermal rating is 95 MW fuel input. District heating temperature to the plant around 60°C and from the plant 115°C. Design data for mechanical design is Water side: 16 Bar(g)/120°C. The mechanical design needs to be selected such that the equipment is fitted in the available space in the existing building.

The dimensions of the available space are: With: 9,6 meters, Height: 14,6 meters, Length: 15,7 meters.

The boiler and flue gas fans shall be located within the available space.

The boiler will be installed during the first half of 2018.

Electricity, heating, solar and nuclear energy

Pajalabostäder AB | Published March 28, 2017  -  Deadline April 24, 2017
cpvs
09300000

Pajala homes AB Pajala Municipality procures thermal heat for the facilities Tallgården and Rönngården with adjacent buildings. The clients want to buy ready heat delivered from a new pellet boiler which tenders entire purchase, install, own and manage.

Plumbing and sanitary works

Tekniska verken i Linköping AB (publ.) | Published March 17, 2017  -  Deadline March 29, 2017
cpvs
45330000, 44615000, 45231112, 50000000

Maintenance and repair of pressure vessels of boilers and related equipment.

Extent:

The contract covers the maintenance and repair of pressure vessels of boilers and related equipment in the Technical plant facilities in southern Östergötland and Sörmland. Work that may occur is the maintenance and repair of boiler tubes, pressurized lines in pannära environment.

Estimated number called off hours per year is about 4 500th

Note that the scope of the assignment is only valued and applies without obligation.

During the contract period, changes occur on the basis of group decisions, operational changes and more that can affect demand and volume. L is obliged to deliver the real need.

Construction work

Borås Energi och Miljö AB | Published March 18, 2017  -  Deadline April 3, 2017
cpvs
45000000, 44615000, 45200000, 45223100, 45223110, 45250000, 45251000, 45251100, 45262000, 45262400, 45262600, 45262680, 71320000, 71323200

The contract concerns the exchange of partition wall, rear wall, primary and secondary superheater in two waste boilers, PVA1 and PVA2.

The exchange is planned on a boiler at a time: PVA2 autumn 2017 and PVA1 autumn 2018. The contract is a turnkey contract in accordance with ABT06 with the Client additions and changes.

Hovås School Conversion oil boiler heating system and measures

Göteborgs Stad, Lokalförvaltningen | Published April 5, 2017  -  Deadline May 4, 2017
cpvs

Base Substitution Boiler 1

Mölndal Energi Aktiebolag | Published February 7, 2017  -  Deadline February 24, 2017
cpvs

Construction works for power plants and heating plants

Karlskoga Kraftvärmeverk AB | Published November 26, 2016  -  Deadline January 13, 2017
cpvs
45251000, 45251140, 45251200, 45262700

In the boilers C1 and C2 burned several fuels where certain recycled fuels classified as waste, thereby obeys the boilers during the requirements of SFS 2013: 253rd Increased requirements for particle separation and that the boiler electrostatic precipitator is from 1984, the company decided to rebuild the existing electrostatic precipitators to bag filters. This request relates to reconstruction of electrostatic precipitator for boiler C1 and option for the reconstruction of electrostatic precipitator for boiler C2.

Värnamo Energi Bor och Lanna Pannanläggningar (16/1)

Värnamo Energi Aktiebolag | Published November 15, 2016  -  Deadline December 11, 2016
cpvs
45251200, 44621200, 45251250, 45262000, 45315100, 45331000, 51900000, 71314000

Procurement of boiler plants, for Lives and Lanna in Värnamo.

Exchange of pellet boiler to ground source at Söderåsen National Park (turnkey) (512-32280-16)

LÄNSSTYRELSEN I SKÅNE LÄN | Published November 11, 2016  -  Deadline December 5, 2016
cpvs
45330000, 45300000, 45331000, 50721000

Exchange of pellet boiler to ground source at Söderåsen National Park (turnkey)

Framework agreements RE FVC plumbing substations 2017-2019 (16/4)

Gislaved Energiring AB | Published November 11, 2016  -  Deadline December 9, 2016
cpvs
45300000, 45320000, 45330000

Procurement of plumbing works of substations, the refurbishment of the existing boiler / electrical rooms in villas and properties for connection to district heating in Gislaved Municipality. includes moving electricity and construction.

Reconstruction of the existing electrostatic precipitator C1 to bag filter (16/1)

Karlskoga Kraftvärmeverk AB | Published November 23, 2016  -  Deadline January 13, 2017
cpvs
45251000, 45251140, 45251200, 45262700

In the boilers C1 and C2 burned several fuels where certain recycled fuels classified as waste, thereby obeys the boilers during the requirements of SFS 2013: 253rd Increased requirements for particle separation and that the boiler electrostatic precipitator is from 1984, the company decided to rebuild the existing electrostatic precipitators to bag filters. This request relates to reconstruction of electrostatic precipitator for boiler C1 and option for the reconstruction of electrostatic precipitator for boiler C2.

Blasting in the solid fuel boiler for CHP Gävle AB 5849

Gävle Energi AB. | Published October 6, 2016  -  Deadline July 20, 2011
cpvs
45100000, 45251230, 45259300

Audience Ad: The procurement is publicly advertised and the bidding process is ongoing. The deadline to submit bids is 11.07.2016. The offer is valid until 12.31.2016. More information can be found by clicking on the specifications in the left menu and subtitle tenders for information on how you should proceed to tender.

Fuel handling system

Mälarenergi AB | Published October 10, 2016  -  Deadline November 8, 2016
cpvs
42164000

Mälarenergi AB is planning to invest in a new combined heat and power (CHP) plant with auxiliary systems and to modernise the existing plant in Västerås. The Project consists of four main parts: A steam boiler of 150 – 180 MWth for combustion of recycled wood fuel, a district heating condensing steam turbine of about 55 – 65 MWe, a flue gas treatment system and a fuel handling system including preparation and storage to supply the boiler with solid fuel. This procurement (Dnr 2016/44) relates to the purchase of a fuel handling system to supply the boiler with solid fuel. The fuel shall be recycled wood, i.e. wood waste (used wood) including demolition wood.