36--Electric Platen

Department of the Army, Army Contracting Command | Published June 25, 2015
cpvs

Electric Heater Platen

Power Rotary / Swaging Machine (10ga) with Accessories, Sahinder IBKS 4.0 (or equivalent)

Department of the Army, Army Contracting Command | Published September 9, 2016  -  Deadline September 20, 2016
cpvs

This is a Combined Synopsis/Solicitation for commercial items, prepared in accordance with FAR Parts 12.6 and 13, and supplemented by additional information contained in this announcement. Red River Army Depot (RRAD), located near Texarkana, TX, requires one Power Rotary / Swaging Machine with compatible rolls and roll sets. Specifications: Sahinler IBKS 4.0 (10ga) or EquivalentThroat Depth - 7.87" minimumCapacity - 10 Gauge minimumRoll Diameter - 5" minimumElectrical - 220V 3-PhaseMotor - 3HP minimumSchedule 80 type (minimum) piping distribution systemHydraulic Top Shaft ControlIncludes Single-Bead, Flattening, and Offset Roll SetsIncludes Compatible 1/2" Flange Roll SetIncludes Compatible Crimp Roll Set Please refer to the attached Combined Synopsis/Solicitation for full specifications, terms and conditions, and proposal instructions. Bids/offers will only be accepted through the FedBizOpps system. FOB Destination, Red River Army Depot, Texarkana, TX 75507.

Hydro-Pneumatic Rivet Machine

Department of the Army, Army Contracting Command | Published March 29, 2016  -  Deadline April 5, 2016
cpvs

100% Small Business Set AsideMinimum Specifications:Designed to remove rivets from heavy duty front and back brake shoesElectrical: 110 Volts, 20 Amps.Cycle time 45 seconds, + or - 5 Seconds.Process rivets up to 1/4 InchWorking pressure: 1,750 PSIMax punch force: 8,000 LBSMax punch stroke: 3 InchesBrake Machinery Sales Model# BMS 1 or equal1 EachShip to: RED RIVER ARMY DEPOTDLA-LMP-QADDRR BLDG 499 ZONE 4 DOOR 37 10TH STREET AND K AVENUETEXARKANA TX 75507-5000Required delivery: 30 Days ADCEvaluation: Low PriceAnticiapted Award NLT 11 April, 2016

PORTABLE ELECTRIC AIR COMPRESSOR

Department of the Army, Army Contracting Command | Published November 25, 2015
cpvs

Doosan Infracore model VP900EWBAL-VS Compressor, Trailer Mounted.

PORTABLE ELECTRIC AIR COMPRESSOR

Department of the Army, Army Contracting Command | Published October 8, 2015  -  Deadline October 23, 2015
cpvs

One (1) each Portable Electric Compressor: Highway trailer mounted with brakes, lights, and safety chains, 575 CFM min, 125 PSI min. Sullair E900HAF or equal.

W--LEASE OF 35 - TON INDUSTRIAL CRANE FOR A PERIOD OF TWELVE (12) MONTHS IN RED RIVER ARMY DEPOT.

Department of the Army, Army Contracting Command | Published September 9, 2015  -  Deadline September 15, 2015
cpvs

The contractor shall provide: 1) One (1) 35 - ton industrial crane to RRAD for a lease period of twelve (12) months. 2) The equipment should be fully functional/operational. The equipment should meet all OSHA safety requirements for industrial cranes. 3) Contractor shall be responsible for delivering the equipment to Red River Army Depot at the beginning of the lease and will be responsible for picking up the equipment from Red River Army Depot at the end of the lease. 4) Contractor is responsible for any maintenance required of the equipment as well as any repairs the equipment may need during the period of the lease. 5)If the equipment goes down for mechanical / electrical / or hydraulic failure it is up to the contractor to either repair the equipment on site within 72 hours of notification of the down equipment or replace the crane with a comparable/equal crane. 6) Contractor shall be required to perform one (1) hour of user training to insure the end user is familiar with the equipment and all its safety mechanisms.

Inspection & Calibration for two (2) Tescom Fire Valve Test Stands model

Department of the Army, Army Contracting Command | Published November 18, 2015  -  Deadline November 25, 2015
cpvs

Scope of Work: 1) The contractor shall provide all personnel, equipment, supplies, facilities, transportation, tools, materials, supervision, and other items to perform yearly inspection & calibration of the two (2) each Tescom Valve Test Stands model NA-134. All Tests shall be in OEM (Kidde) standards are fully operational and capable of testing (750psi) and newer(900psi), and Calibrate equipment for all functions the OEM originally designed the equipment to perform. 2) The contractor shall provide qualified and experienced personnel in the inspection, testing and calibrate of the two (2) each Tescom Valve Test Stands model NA-134; at Red River Army Depot, Texarkana, Texas. 3) Provide all Labor and Materials necessary to inspect two (2) each Tescom Fire Valve test stands model # NA-134 to insure test stands are fully operational and capable of testing (750psi) and newer (900psi). Calibrate equipment for all functions the OEM originally designed the equipment to perform. 4) The unit will be inspected & calibrated to insure that all specifications and tolerances will be In accordance with OEM (Kidde) standards Document # 12308790 which stated: Continuity test; .87 +/- .24Ohms, 1500psig (1800psig for newer valve) proof test: 5 minutes and observe pressure loss, check tank full switch (newer valves), electrical fire test (fire less than 10 milliseconds, pull test, initial leakage test (monitor pressure release for 1 minute). Period of Performance: One Base Year of 12 months and three (3) 12-months option years, for a total of 4 years. Deliverables: Contractor upon completion of inspection and calibration of the Tescom NA-134 equipment will provide a letter of calibration valid for one year (12 months) from the date of inspection and calibration.

OVERHEAD BRIDGE CRANE SYSTEM

Department of the Army, Army Contracting Command | Published January 7, 2016  -  Deadline January 18, 2016
cpvs

Purchase Description Overhead Bridge/Hoist Crane System Rubber Products Division Red River Army Depot 1. General: This purchase description is for the purchase and installation of one free-standing overhead bridge/hoist crane system in Rubber Products Division, Building 493; Red River Army Depot. 2. Purpose: There is a requirement for an overhead bridge/hoist crane system that is capable of handling tire/wheel assemblies onto and off of tire assembly machines throughout the tire assembly process. Crane system shall consist of three bridge cranes; 2 ea. 1000lb. and 1 ea. 4000 lb. cranes. Bridge system shall be 18 ft., max. height, 22 ft. max width, and run along 100 ft. runway divided into 20' spans. This system shall be located at the South end of Building 493. 3. Specifications: The required equipment and or components, their quantities and part numbers are listed as follows: a. Two (2) each 1000 lb. bridge system b. One (1) each 4000 lb. bridge system c. Two (2) each 1000 lb. pneumatic chain hoist d. One (1) each 4000 lb. pneumatic chain hoist e. Necessary rail supporting legs for 100 ft. run of bridge system f. Necessary rail for 100 ft. bridge support g. Necessary pneumatic lines to run from bldg. air system 4. Installation: a. Bridge System: Complete turn-key installation of the Bridge systems and Hoists described by this Purchase Description by the vendor is required. Upon completion of the installation, the system shall be fully functional and meet all of the requirements specified by this Purchase Description. Different load bridge systems shall be located in such that the 4000 lb. bridge and hoist shall be located at the North end of the bridge system and the two 1000 lb. load systems shall be located on the South side of the 4000 lb. system. b. Tools and Equipment: All hand or power tools, equipment such as forklifts, man lifts, ladders, and scaffolding required to install the bridge systems and hoist are the responsibility of the vendor and will not be supplied by the government. c. Compressed air supply: Compressed air supply required to make the hoist functional will be the responsibility of the government up to the point of the bridge crane structure. Compressed air hoses, festooning, and securing the airlines to the bridge structure will be the responsibility of the vendor. 5. Warranty - One year minimum warranty required or the Manufacturer's standard Warranty if greater. 6. Parts Catalogs, Installation, Maintenance and Operating Instructions - The successful Contractor shall provide, as a minimum, two (2) copies of complete maintenance and operating instructions and parts for the equipment supplied under this purchase description. All documentation will be submitted in PDF format on CD or DVD along with two (2) hardcopies. 7. Quality Assurance Provision: a. Examination - The furnished equipment shall be examined for compliance with the requirements specified in section 3 of this purchase description. Any redesign or modification of the Contractor's standard product to comply with the specified requirements shall receive particular attention for adequacy and suitability and must be communicated to the Government with the specific changes in the bid. Noncompliance with any specified requirements or presence of one or more defects preventing or lessening maximum efficiency shall constitute cause for rejection. b. Responsibility for Inspection - The Contractor shall be responsible for the performance of all inspection requirements to provide a mechanically sound unit which will meet or exceed the requirements of section 3. The Government reserves the right to perform inspections which are deemed necessary to assure supplies and services conform to prescribed requirements. c. Safety and Health Requirements - The bridge crane(s) shall be fitted with safety devices or coverings for any parts that present safety hazards. All equipment furnished under this purchase description shall comply with applicable OSHA 1910 and NFPA 70 standards. The bridge crane(s) shall include provisions to isolate and lock out all sources of hazardous energy, either input to the machine or generated by the machine, to ensure safety of operation and maintenance personnel. Electrical lockout devices shall conform to the requirements of NFPA 79. Lockout devices for electrical or any other type of hazardous energy shall be designed to allow full operational compliance with the requirements of OSHA Standard 29 CFR. All system and operation standards shall comply with OSHA standards on Human Factors Engineering (Ergonomics). d. Lockout / Tagout (LOTO) Requirements - Equipment Contractor shall furnish a graphical, machine-specific LOTO procedure that clearly and specifically describes the steps necessary to establish a zero-energy state for the equipment in accordance with the requirements of OSHA Regulation CFR 1910.147. This procedure shall be printed on a durable material suitable for posting on the equipment. All LOTO locations on the equipment shall be clearly identified with a durable label keyed to the LOTO procedure. Contractor shall furnish the procedure in an electronic format so the information can easily be transferred into a maintenance management data system. e. Total Preventive Maintenance (TPM) Requirements - Equipment Contractor shall furnish a Maintenance and Operations manual that contains a list of preventive maintenance tasks required to keep the equipment operating at peak efficiency. The tasks shall be listed by frequency. Each service point identified in the maintenance task list shall be clearly labeled to permit easy identification. Contractor shall furnish the preventive maintenance task list in an electronic format (Para 3.13) so the information can easily be transferred into a maintenance management data system. f. Packing and Shipping - The Contractor is responsible for shipment of all parts, materials and equipment supplied, to RRAD. The Contractor shall preserve and package the material supplied in a manner to afford protection against deterioration and damage from source to RRAD. The equipment shall be packed in a manner to assure carrier acceptance and safe delivery to destination, Red River Army Depot. Container shall conform to carrier rules applicable to mode of transportation used.