The subject of procurement is: remedial clamps and couplings.
The client shared procured the group:
Group 1. The recovery clamps
- Corrective collars must be applicable to repair damage to all water supply pipelines (of materials: LJ W, Th, AC, HDPE, PVC, Ductile)
- Repair clamp must be completely made of stainless steel AISI 304, EN 1.4301 (18% Cr and 10% Ni); design with no sharp edges to avoid injury hand fitters,
- Bolts (M12 and M16) must be protected against scuffing a special coating,
- On each for repair clamp has to be handle for ease of handling and installation,
- Number of screws for clamping collars should the width of remedial clamps least be as follows:
L = 200 mm; min. 3 screw, L = 300 mm; min. 5 screws, L = 400 mm; min. 7 screws, L = 500 mm; min. 9 screws,
- Each repair clamp on the chassis must have engraved label manufacturer and type clamps,
- Remedial clamps must be individually packed in a cardboard box to protect it from damage during transport and handling at the warehouse.
GROUP Restoration second connectors
Technical description specified in the bill.
The subject of the procurement is: Tractors and attachments of tractors and attachments
Group 1. Tractors with joints for arranging and maintaining green areas
Group 2. A communal tractor for working with connectors
Group 3. Connector for tractor - salt spreaders
Group 4. Plug for mower and mower tractor
Group 5. Composting surface cleaner.
The subject of the procurement is: Tractors and attachments of tractors and attachments, pursuant to item 4 DON.
The subject of the procurement is: Tractors and attachments of tractors and attachments, according to item 4 DON.
The subject of the procurement is: Tractors and attachments of tractors and attachments, in accordance with point 4, para.
One-year supply of medical supplies for cardiac surgery.
Medical supplies (canes, electrodes).
Medical supplies (dentures, patches, diaphragms).
Medical consumables (holder and clamp).
Medical supplies (clip, prosthesis, resorptive hemostatic).
Medical consumables (liquids).
Medical consumables (clips, electrodes, connectors).
Medical supplies (canes, cartridges for portable blood analyzers).
Medical supplies (canes, catheters).
Medical supplies (catheters).
Medical consumables (systems, connectors, cannulaes).
Medical supplies (dentures).
Medical supplies (patches, electrodes, clips).
Medical supplies (vascular prosthesis, balloon expansion valve).
Medical supplies (clips, duvets).
Medical consumables (invasive pressure measurement sets, contact plates).
The subject of procurement is: remedial clamps and couplings. The client shared procured the group:
Group 1. The recovery collars.
- Corrective collars must be applicable to repair damage to all water supply pipelines (of materials: LJ W, Th, AC, HDPE, PVC, Ductile)
- Repair clamp must be completely made of stainless steel AISI 304, EN 1.4301 (18% Cr and 10% Ni); design with no sharp edges to avoid injury hand fitters,
- Bolts (M12 and M16) must be protected against scuffing a special coating,
- On each for repair clamp has to be handle for ease of handling and installation,
- Number of screws for clamping collars should the width of remedial clamps least be as follows: L = 200 mm; 3 min screw, L = 300 mm; 5 min screw, L = 400 mm; 7 min screw, L = 500 mm; min 9 screws,
- Each repair clamp on the chassis must have engraved label manufacturer and type clamps,
- Remedial clamps must be individually packed in a cardboard box to protect it from damage during transport and handling at the warehouse.
Group 2. Restoration connectors.
Technical description specified in the Bill of Quantities.
Tires for vehicles.
Tires for freight vehicles.
Tires for work machines and connectors.
Tires for personal, terrain and light duty vehicles and motorcycles.