Call +44 800 9755 164

Public tenders for consultant in Bergen Norway

Find all Consulting tenders in the world.
Finding business opportunities has never been easier.

Results for consulting. Make a new search!

Technical testing, analysis and consultancy services

Hordaland fylkeskommune | Published January 26, 2017  -  Deadline February 20, 2017
cpvs
71600000, 71000000, 71620000

In accordance with NS 3424 ‘Condition Evaluation for Structures’, condition evaluations with supplementary reports shall be carried out for sixth form colleges. See the attached list of schools.

For further information about the buildings, see the attached fact sheet for each school.

It is extremely important that the structure evaluation with supplementary report gives exact advice so that it is a good tool for the preparation of the maintenance plan and budget. It shall also form the basis for systematic upgrading of the buildings/facilities and any adjustments to the users needs.

In accordance with NS 3424 ‘Condition Evaluation for Structures’, condition evaluations with supplementary reports shall be carried out for sixth form colleges. See the attached list of schools.

For further information about the buildings, see the attached fact sheet for each school.

It is extremely important that the structure evaluation with supplementary report gives exact advice so that it is a good tool for the preparation of the maintenance plan and budget. It shall also form the basis for systematic upgrading of the buildings/facilities and any adjustments to the users needs.

The condition evaluation shall include all discipline categories in the building component table, such as:

2 - Building, also including fire.

3 - HVAC and sanitary installations.

4 - Electricity.

5 - Tele and automation.

6 - Other installations.

7 - Outdoors.

The condition report will be prepared on level 2.

Regarding fire, only the condition of the existing fire protection in the building will be inspected.. A full fire review of the buildings shall not be carried out.

Environmental mapping reports have been created for most of the buildings. These will be mad available to the company that shall carry out the evaluations.

Hordaland fylkeskommune has politically approved a maintenance strategy that states the the buildings should be ‘sound’. The schools shall have Public Health Authority certification and the condition rating of the buildings should not be less than 1.0/ This forms the basis for all maintenance planning in Hordaland fylkeskommune.

In order to map the functionality of the buildings in relation to the user, a preliminary risk assessment shall be carried out in cooperation with a user representative appointed by the school. The objective of this is to ascertain the need for initiatives/reconstruction etc. so the facilities are in optimal condition in relation to the user/school operation.

The initiatives shall be individually listed and roughly estimated.

The work of condition evaluating shall be carried out in close cooperation with the operations manager and the area manager who is responsible for and has knowledge of the buildings. See the attached list with contact persons.

The user/school representative who has knowledge of the school's/users' need must be present for site inspections and meetings.

In the first instance a school shall be evaluated. This evaluation shall be presented to relevant persons at The Property Department and be comprehensively reviewed by HFK so that the level and form are clarified before proceeding with the remainder of the buildings.

IT services: consulting, software development, Internet and support

Konkurransetilsynet | Published February 18, 2017  -  Deadline March 15, 2017
cpvs
72000000, 48000000

The contract for system integration/operation support/consultancy service for IT systems shall, as a starting point, include the procurement of new systems, as well as further development and consultancy/support for the contracting authority's current systems.

  • 1