Industrial machinery

PCC Rokita SA | Published July 14, 2015
Winner
Instal-Rzeszów Sp. z o.o.
cpvs
42000000

The subject of the call is "execution, delivery, unloading and installation of the water dripping wet T-402 with its isolation" within the PCC Rokita SA in Brzeg Dolny (56-120) Sienkiewicz Street 4, according to the design documentation developed by the Group Azoty Polish Chemical Consortium Sp. z oo

Industrial machinery

PCC Rokita SA | Published June 6, 2015  -  Deadline June 8, 2015
cpvs
42000000

1. The subject of the call is "execution, delivery, unloading and installation of the water dripping wet T-402 with its isolation" within the PCC Rokita SA in Brzeg Dolny (56-120) Sienkiewicz Street 4, according to the design documentation developed by the Group Azoty Polish Chemical Consortium Sp. z oo;

Construction work

PCC Rokita SA | Published November 4, 2015
Winner
PCC Apakor Sp. z o.o.
cpvs
45000000, 44000000

The subject of the call is the execution of cross-industry with the launch installations carried out under the investment order entitled "The use of steam condensate and caustic wypadowego of Propylene Oxide Plant at PCC Rokita SA" at the PCC Rokita SA in Brzeg Dolny (56-120) Sienkiewicz Street 4, according to the design documentation developed by the Group Azoty Polish Chemical Consortium Sp. z oo, in the following areas: - mechanical engineering - piping - Installation industry - industry ACP - electric industry.

Construction work

PCC Rokita SA | Published August 26, 2015  -  Deadline September 9, 2015
cpvs
45000000, 44000000

The subject of the call is the execution of cross-industry with the launch installations carried out under the investment order entitled "The use of steam condensate and caustic wypadowego of Propylene Oxide Plant at PCC Rokita SA" at the PCC Rokita SA in Brzeg Dolny (56-120) Sienkiewicz Street 4, according to the design documentation developed by the Group Azoty Polish Chemical Consortium Sp. z oo ,, in the following areas: - Mechanical Industry - piping. - Installation industry. - ACP industry. - Electrical Industry.

Construction work

PCC Rokita SA | Published August 1, 2015  -  Deadline August 10, 2015
cpvs
45000000, 44000000

The subject of the call is to the execution of cross-industry with the launch of installations carried out under the investment order entitled "Use of condensate steam and caustic wypadowego of Plant propylene oxide at PCC Rokita SA" at the PCC Rokita SA in Brzeg Dolny (56-120) Sienkiewicz Street 4, according to the design documentation developed by the Group Azoty Polish Chemical Consortium Sp. z oo ,, in the following areas: - mechanical engineering - piping - Installation industry - industry ACP - electric industry.

Industrial machinery

PCC Rokita SA | Published June 13, 2015
Winner
PCC Apakor Sp. z o.o.
cpvs
42000000

The subject of the call is "execution, delivery, unloading and installation of the water condensates V-23200800, together with its isolation" within the PCC Rokita SA in Brzeg Dolny (56-120) Sienkiewicz Street 4, according to the design documentation developed by the Group Azoty Polish Chemical Consortium Sp. z oo, in terms of: - Industry Cameras - Condensate and caustic wypadowego V-23200800, no studies: - 1201-02.08-501 REV.B. - 1201-02.09-515 Rev.B, - 1201-02.09-516 REV .B - 1201-02.09-517 - 1201-02.09-518 Rev.B - 1201-02.09-519 - 1201-02.09-520 - 1201-02.09-521 - 1201-02.09-522 - 1201 -02.09-523 - 1201-02.09-524 - 1201-02.09-525., - 1201-02.09-526 - 1201-02.09-527 - 1201-02.09-528 - 1201-02.09-529 - 1201 -02.09-530, - 1201-02.09-531, - 1201-02.09-532, - 1201-02.09-533, - plans and sections bowls, - 1201-00.05-05; 2. The general scope of work includes: - the execution and delivery to the premises of PCC Rokita SA tank - hot insulation performance, - installation of the water in the basin of reinforced concrete on the item. approx. -5,5m, - providing as-built documentation; 3. guidelines of hot insulation: - thermal insulation (eg. The type of Isover Ultimate), - thermal resistance> 400 degrees C, - bulk density of> 80 kg / m3, - tolerance thermal conductivity + 0 / -10%, - flammability> B2 ( DIN 4102 or equivalent), - net oplotcza: hexagonal wire> 0.7 mm - required thermal conductivity: 0,052-0,047 W / mK - protective coat - plate: Al-Zn coated on both sides coating, 55% Al, 43, Zc 4%, 1.5% Si), - coating thickness> 20 microns - the thickness of the sheet 0.8-1 mm - insulation must be done in a waterproof, - flashings should be sealed with silicone putty, 20-30 cm - insulation supporting structures should be arranged along the axis of the tank at not less than 1 m,

Industrial machinery

PCC Rokita SA | Published May 6, 2015  -  Deadline May 14, 2015
cpvs
42000000

The subject of the call is "execution, delivery, unloading and installation of the water condensates V-23200800, together with its isolation" within the PCC Rokita SA in Brzeg Dolny (56-120) Sienkiewicz Street 4, according to the design documentation developed by the Group Azoty Polish Chemical Consortium Sp. z oo, in terms of: - Industry Cameras - Condensate and caustic wypadowego V-23200800, no studies: - 1201-02.08-501 REV.B. - 1201-02.09-515 Rev.B - Rev.B 1201-02.09-516 - 1201-02.09-517 - Rev.B 1201-02.09-518 - 1201-02.09-519 - 1201-02.09-520 - 1201-02.09- 521 - 1201-02.09-522 - 1201-02.09-523 - 1201-02.09-524 - 1201-02.09-525. - 1201-02.09-526 - 1201-02.09-527 - 1201-02.09-528 - 1201-02.09-529 - 1201-02.09-530 - 1201-02.09-531 - 1201-02.09-532 - 1201-02.09-533 - plans and sections bowls - 1201-00.05-05 The general scope of work includes: - Execution and delivery to the premises of PCC Rokita SA reservoir; - Execution of hot insulation - Installation of the reservoir in the basin of reinforced concrete on the item. approx. -5,5m; - Provide guidance as-built documentation of hot insulation - Thermal insulation (eg. The type of Isover Ultimate) - Thermal resistance> 400 deg C - The bulk density of> 80kg / m3 - thermal conductivity tolerance + 0 / -10% - Flammability> B2 (according to DIN 4102 or equivalent) - Grid oplotcza: hexagonal wire> 0.7 mm - Required thermal conductivity: 0,052-0,047 W / mK - Protective jacket: - Sheet: Al-Zn coated on both sides coating of 55% Al, 43.4% Zc, 1.5% Si ) - Coating thickness> 20 .mu.m - The thickness of the sheet metal 0,8-1mm - Insulation should be made as watertight; - The flashing should be sealed with silicone putty; 20-30cm; - Insulation support structures should be arranged along the axis of the tank at least every 1m;